Owner's Manual

INSTALLATION
INSTALLATION:
1. Operation temperatures permit safe installation of this steam table with in 1” of a combustible wall or
partition.
2. Make sure that the operating location is in an area where the ambient temperature is held constant
(minimum 70°F). Please avoid areas such as near exhaust fans and air conditioning ducts.
3. Place unit on a stable, level floor. The unit must be leveled, both front and back and left to right, in
order to maintain an equal water depth throughout the wells.
4. The voltage and wattage ratings of this steam table are given on the device name plate. Connect the
steam table to a circuit having a voltage and type of similar current to that on the rating plate.
5. Before plugging unit into wall outlet or permanently electric connecting, the unit should be adjusted to
the desired height and aligned with other equipment. For supply connections use No.12 AWG or larger
wires suitable for at least 194°F. Use copper wire for power supply or suitable copper to aluminum wire
connector.
6. The Body of the appliance should be grounded by connecting the ground stud provided in the junction
box to a good electrical ground, such as a water pipe, a steam pipe, or a grounded supply conduit.
7. The steam table is not fused so it must be connected to a fused circuit equipped with suitable
disconnect means, as required by local code authorities.
8. Always use standardized steam table pans.
9. When you use the steam table with the casters, the steam table should displace after disassembling
the power code to avoid damage of the cable.
10. When you use the steam table with the casters, the brakes on the casters should be locked before
using the steam table.
11. Please be careful when installing steam table; the cable must not get in contact with metal surface
of steam table.
12. Do not install roll-top cover on any wells.
4