Instructions

59
EN
5.1 Description of the safety functions
Obstacle detection
The movement of the belt is monitored. If the roller
shutters hit an obstacle in the DOWN ( t ) direction, the
belt will stop moving and the RolloTron Basic DuoFern
1200 is switched off.
i
Once the system has switched off, it is not
possible to directly operate the drive in the
same direction.
First, run the belt winder back in the op-
posite direction and remove any possible
obstacle.
Then it is possible to operate the drive in
the original direction again.
Overload cut-off
The RolloTron Basic DuoFern 1200 is equipped with
an overload cut-off system.
If the drive jams in the UP ( ▲ ) direction (for example, due
to ice), the RolloTron Basic DuoFern 1200 is switched off.
First, remove the cause of the overload.
Once the cause has been rectified, the RolloTron
Basic DuoFern 1200 is fully operational again in both
directions.
i
There is a risk of injury if the obstacle detection is
not working.
The belt must be wound on as evenly as possible to
ensure safe and correct functioning of the obstacle
detection function.
Please ensure that the belt winds as straight and
evenly as possible into the device during its subse-
quent cycle after the obstacle detection system has
triggered.