Instructions

57
EN
i
4.1 Operating Buttons and Indicator Light
Pos. Symbol Description
1)
2)
+
Up/Stop button + Down/Stop button
The roller shutters travel up / down or stop
3) Indicator Light - Status Display
green flashes
briefly
continuous
light
Connection is active
When configuring the sunshine position
5 sec = connection / disconnection was successful
5 sec = clearing was successful
red flashes
briefly
flashes
briefly
continuous
light
Return signal when pressing the setting buttons
Disconnect or clearing is active
When configuring the end points
Resetting is carried out
The running time limit is triggered
5 sec = connection / disconnection failed
10 sec = automatic functions = ON
4)
Set button
Setting both end points
5)
AUTO
AUTO button
Switching the automatic functions on/off
6)
DuoFern button (connect / disconnect)
Logging on/off in the DuoFern radio network
1)
2)
3)
4)
5)
6)