Instructions

33
EN
i
13. Initial commissioning with the help of the installation wizard
6. Set the upper end point.
6.1 Press and hold the Up button.
The roller shutter travels up.
6.2 Tighten the belt slightly, until it is
tensioned by the weight of the
roller shutters.
6.3 Release the Up button, as soon as
the roller shutter reaches the desired
position for the upper end point.
The roller shutter stops.
6.4 / If necessary, the upper end point can
be corrected once more.
6.5
Save the upper end point.
ATTENTION!
Setting the wrong upper end point may lead to
overload or damage the superrollo GW250 / GW255
or the drive.
Do not set the upper end point right up to the limit
stop.
Release the Up button promptly and never allow it
to extend beyond the respective end point.
7. Next the lower end point must be set,
see the next page.
i
Please ensure that the belt is not excessively
slack when reaching the lower end point.