Instructions
Table Of Contents
- 1. This manual...
- 1.1 How to use this manual
- 2. Hazard symbols
- 2.1 Levels of danger and signal words
- 2.2 Symbols and depictions used
- 3. Safety instructions
- 3.1 Intended use
- 3.2 Improper use
- 3.3 Required expert knowledge of the installer
- 3.4 Glossary - definition
- 4. Included in delivery
- 5. General view of the operating unit
- 5.1 General view of the installation housing
- 5.2 Electrical connections
- 5.3 Display and its symbols
- 5.4 Views of the standard display
- 6. Product description
- 6.1 Overview of functions
- 6.2 Functions and sample applications
- 7. Technical specifications
- 7.1 Factory settings
- 7.2 Conduct in the event of a power failure
- 8. Safety instructions for the electrical connection
- 8.1 Important information prior to the electrical connection and installation
- 8.2 Electrical connection
- 8.3 Connection diagram with a 230 V control valve
- 8.4 Connection diagram with a 24 V control valve
- 9. Installation after the electrical connection
- 10. Introduction to opening the menus and setting the functions
- 11. Initial commissioning with the help of the installation wizard
- 12. Manually changing the target temperature
- 13. Switching automatic mode on/off directly on the standard display
- 14. Calling up and displaying weather data
- 15. Menu overview
- 15.1 Menu 1 - Switching automatic mode on/off
- 15.2 Menu 2 - Setting automatic heating phases
- 15.3 Menu 3 - Setting target temperatures centrally
- 16. Menu 9 - System settings
- 16.1 Menu 9.1 - Setting the time and date
- 16.2 Menu 9.5 - Setting the week programme
- 16.3 Menu 9.7 - Installer settings
- 16.4 Menu 9.7.1 - Setting the heating mode
- 16.5 Menu 9.7.2 - Setting the sensor offset
- 16.6 Menu 9.7.3 - Setting the hysteresis / minimum on-time
- 16.7 Menu 9.7.4 - Setting the valve protection
- 16.8 Menu 9.7.5 - Setting the frost protection
- 16.9 Menu 9.7.6 - Setting the valve mode
- 16.10 Menu 9.7.7 - Performing a sensor test
- 17. Menu 9.8 - Device settings
- 17.1 Menu 9.8.1 - Switching the automatic summer/ winter time on/off
- 17.2 Menu 9.8.3 - Setting the display lighting
- 17.3 Menu 9.8.5 - Switching the button lock on/off
- 17.4 Menu 9.8.6 - Setting the holiday mode incl. the setback temperature
- 17.5 Menu 9.8.7 - Setting the party mode incl. the comfort temperature
- 17.6 Menu 9.8.0 - Displaying the software version
- 18. Menu 9.9 - DuoFern settings
- 18.1 Menu 9.9.1 - Logging DuoFern devices on/off
- 18.2 Menu 9.9.2 - Setting the DuoFern mode
- 18.3 Menu 9.9.3 - Setting the transmission channel
- 18.4 Menu 9.9.4 - Switching the weather data on/off
- 18.5 Menu 9.9.5 - Displaying the DuoFern address (radio code)
- 19. Logging on to the HomePilot®
- 20. Deleting all settings, software reset
- 21. Carrying out a hardware reset
- 22. Error messages
- 23. Dismantling
- 24. Simplified EU Declaration of Conformity
- 25. Accessories
- 26. Warranty conditions
82
EN
16.4 Menu 9.7.1 - Setting the heating mode
You can set the DuoFern Room Thermostat 2 for one of the
following heating modes.
There are three heating modes available:
[ 1 ] Room temperature controller (factory setting)
The heating is switched on when the room temperature
drops below the set target temperature.
[ 2 ] Room temperature controller with limiter
This function can be used for floor heating with particularly
sensitive floor coverings. Excessive cooling of the floor can
also be prevented with additional heat sources (e.g. fireplace)
by defining a minimum floor temperature. It is absolutely
essential to connect the device to the external Remote Sensor
9485-F for this heating mode.
The heating is switched on when the room temperature
drops below the set target temperature. The room
temperature is measured with the internal sensor.
The floor temperature is measured by the external Remote
Sensor 9485-F regardless of the room temperature. The set
minimum and maximum floor temperature is taken into
account in the heating control and limited accordingly.
[ 3 ] Cooling function
The air conditioning is switched on when the room
temperature exceeds the set target temperature.
i
Additional parameters must be set in each
heating mode.