Instructions

66
EN
NOTE!
The drive is preset to stage 3 by the supplier. If required
(e. g. if the power level is too low) you can subsequently
adjust the power limiting setting.
If the power level is too low, the door movement
will be impaired, particularly if the mechanical
structure of the door is not well balanced.
1. Press "P" for approx.
5 seconds.
3. Press "P", the display
shows "7" (stage 3).
After resetting of the power level, it is absolutely necessary to repeat the reference run for power limiting
and to conclude the programming again.
Risk of injury if reference run is not undertaken for purposes of power measurement. Also there is a risk
of injury during the reference run process, as the drive develops a high degree of force.
If the subsequent adjustment does not restore correct operation, please contact our authorised Service
department.
5. Press "P", in order
to store the setting.
6. IMPORTANT
Repeat reference run
for power limiting
(refer to page 65).
7. Conclude programming
(refer to page 71 /
method 1).
11.4 Adjust power limiting as required
Power level
Low High
Factory setting
4. Press "+" or press "–" to
select the stage.
2. Press "+".
(if necessary press several
times) until "4" is displayed.