19.2 Menu 9.2 - Congure motor running time
Conguring the running time allows specic targeted positions to
be assumed based on the running time and roller shutter position.
The run time setting must be congured if:
◆ you intend to use the ventilation position function, see
page 89.
◆ you intend to use the sunshine position function (only if
automatic slat function is activated, see page 97).
◆ you intend to congure and have the system move to an
arbitrary position, see page 37.
The running time can be detected directly by the Troll Comfort
DuoFern or you may, for example, measure and congure it with
the help of a stopwatch.
NOTE
◆ Tubular motor running times can vary depending on temperature.
For this reason, targeted movement to a specic position is subject
to certain tolerances.
◆ The running time must be congured as precisely as possible in order
for the desired position to be reliably assumed.
◆ The running time must be recongured if the end points are changed.
◆ If the running time is congured, for example, with the help of a
stopwatch, then the speed should be measured in the up direction
and approx. 10% should be added.