18.5.1 Light sensor connection when using the supplied frame [2].
1. Carefully pull the operating unit [ 1 ] away from the installation
housing [ 3 ].
2. Insert the light sensor plug * [ 6 ] into the socket [ 7 ] on the
rear of the operating unit [ 1 ].
3. Feed the sensor cable into the cable bushing in the frame [ 2 ]
and guide it out.
4. Carefully replace the operating unit [ 1 ] with frame [ 2 ] back
onto the installation housing [ 3 ].
* Accessories, see page 122.
Excessive bending can damage the sensor cable.
The sensor cable is a bre optic cable. Avoid excessive bending or