12. Safety instructions for electrical connection
Danger due to electric shock when working on all
electrical systems.
The electrical connection and all work on electrical systems
must only be carried out by a qualied electrician in accord-
ance with the connection instructions in these operating
instructions.
Carry out all installation and connection work only in an
isolated, zero-volts state.
Disconnect all phases of the mains power supply cable and
secure it to prevent any reconnection.
Check the system for a zero-voltage status.
Prior to connecting, compare the information about voltage /
frequency on the device with that of the local electrical grid
operator.
Incorrect wiring may lead to short-circuits and destroy
the device.
Follow the pin assignment detailed in the wiring diagram.
Follow all the electrical connection specications in the
operating instructions of your tubular motor and that of
the external controller (when using E1/E2).
Connection of a second phase to E1 or E2 will cause the
Troll Comfort DuoFern to be damaged.
When inputs E1 / E2 are used, they must always be con-
nected to the same phase.
If another phase is connected, the incorrect mains voltage
(380 V / 50 Hz) will be applied to the inputs and damage
the Troll Comfort DuoFern.