Instructions
26
i
EN
12. Safety instructions for electrical connection
Danger due to electric shock when working on all
electrical systems.
◆ The electrical connection and all work on electrical systems
must only be carried out by a qualied electrician in accord-
ance with the connection instructions in these operating
instructions.
◆ Carry out all installation and connection work only in an
isolated, zero-volts state.
◆ Disconnect all phases of the mains power supply cable and
secure it to prevent any reconnection.
◆ Check the system for a zero-voltage status.
◆ Prior to connecting, compare the information about voltage /
frequency on the device with that of the local electrical grid
operator.
Incorrect wiring may lead to short-circuits and destroy
the device.
◆ Follow the pin assignment detailed in the wiring diagram.
◆ Follow all the electrical connection specications in the
operating instructions of your tubular motor and that of
the external controller (when using E1/E2).
Connection of a second phase to E1 or E2 will cause the
Troll Comfort DuoFern to be damaged.
◆ When inputs E1 / E2 are used, they must always be con-
nected to the same phase.
◆ If another phase is connected, the incorrect mains voltage
(380 V / 50 Hz) will be applied to the inputs and damage
the Troll Comfort DuoFern.