Instructions

21
i
EN
10.2 DuoFern network function table
DuoFern functions Value range Factory setting
A B C D E F G
26. Reset via radio (3-stage) - -
27. Single-button operation - -
28. Jog mode - -
29. Blinds mode on / o O
30. Standard slat position
#
0 % - 100 % 0 %
31. auto Tilt after manual stop direction "Down"
#
on / o On
32. auto Tilt in sunshine position
#
on / o O
33. auto Tilt in ventilation position
#
on / o O
34. auto tilt after moving to a %-position
#
on / o On
35. Slat run time
#
100 ms - 5000 ms 1500 ms (1.5 s)
36. Motor dead time 0 ms / 160 ms / 480 ms 0 ms (o)
37. Manual operation lamp
##
on / o -
38. Unit / light mode
##
Unit / light mode Light mode
39. Stairwell function
##
on / o O
40. Stairway time (impulse duration)
##
100 ms - 3276 s 3 minutes (180 s)
#
only with Venetian blinds mode active /
##
only with lamp function activated