Instructions

39
i
i
EN
28. Technical Specifications
External dimensions control unit [ 1 ]: 50 x 50 x 12 mm (according to DIN 49075)
Nominal voltage: 230 V / 50 Hz; 230 V / 60 Hz
Max. switching capacity: 8 (4) A µ (Type 1B)
Standby consumption: < 0.4 W
Extension inputs: 2 (E1 and E2)
Connection diameter: 1.5 mm²
Installation depth: 32 mm
Permissible ambient temperature: 0 to 40°C
Data retention: permanent
Protection class: II (only for use in dry areas)
Transmission frequency: 434.5 MHz
Transmission power: max. 10 mW
Range: indoors approx. 30 m * / outdoors approx. 100 m
* depending on the building structure
29. Factory settings
Automatic: On
Automatic time: On
Automatic dawn function: Off
Automatic dusk function: Off
Automated solar function: Off
Sunshine position: 50 %
Motor running time: 150 seconds
Ventilation position: Off / 80 %
Blinds mode: Off, tilting time: = 1.50 seconds
Auto tilt to: - Sunshine position: Off
- Ventilation position: Off
Auto tilt after: - Moving to a target position: On
- Manual stop in direction "Down" On
Standard slat position: 0 %
Motor dead time: Off
Jog mode: Off