Instructions

23
EN
11.2 Logging off DuoFern transmitters
1.
+
Activate logout mode.
Simultaneously press and hold the buttons for
approx. 4 seconds.
The timer LED flashes red:
Logout mode remains active for approx. 120 seconds.
2.
Switch the desired DuoFern transmitter to logout mode.
3.
Pay attention to the timer LED.
flashes red
Logout mode is active.
green (for 5 seconds)
Log off was successful. Afterwards, the LED will light up red
again, if the automatic timer has been activated.
red
The logout process failed,
for example if:
An attempt was made to log-off a DuoFern transmitter
that is not logged-on.
4.
Log the next DuoFern transmitter on / off. In order to do so, repeat steps 1 to 2.
5.
Cancel the logout process.
You can cancel the logout process at any time by briefly
pressing the [ SET/Stopp ] key.