9.1 Safety instructions for electrical connection
Danger due to electric shock when working on
all electrical systems.
◆ The electrical connection and all work on electrical systems must only be carried out by
a qualied electrician in accordance with the connection instructions in these operating
instructions.
◆ Carry out all installation and connection work only in an isolated, zero-volts state.
◆ Disconnect all phases of the mains power supply cable and secure it to prevent any
reconnection.
◆ Check the system for a zero-voltage status.
◆ Prior to connecting, compare the information about voltage / frequency on the device
with that of the local electrical grid operator.
Incorrect wiring may lead to short-circuits and
destroy the device.
◆ Follow the pin assignment detailed in the wiring diagram.
◆ Follow all the electrical connection specications in the operating instructions of your
tubular motor and that of the external controller (when using E1/E2).
Connection of a second phase to E1 or E2 will cause the
Troll Basic DuoFern to be damaged.
◆ When inputs E1 / E2 are used, they must always be connected to the same phase.
◆ If another phase is connected, the incorrect mains voltage (380 V / 50 Hz) will be
applied to the inputs and damage the Troll Basic DuoFern.