9.1 Safety instructions for electrical connection
Danger due to electric shock when working on
all electrical systems.
The electrical connection and all work on electrical systems must only be carried out by
a qualied electrician in accordance with the connection instructions in these operating
instructions.
Carry out all installation and connection work only in an isolated, zero-volts state.
Disconnect all phases of the mains power supply cable and secure it to prevent any
reconnection.
Check the system for a zero-voltage status.
Prior to connecting, compare the information about voltage / frequency on the device
with that of the local electrical grid operator.
Incorrect wiring may lead to short-circuits and
destroy the device.
Follow the pin assignment detailed in the wiring diagram.
Follow all the electrical connection specications in the operating instructions of your
tubular motor and that of the external controller (when using E1/E2).
Connection of a second phase to E1 or E2 will cause the
Troll Basic DuoFern to be damaged.
When inputs E1 / E2 are used, they must always be connected to the same phase.
If another phase is connected, the incorrect mains voltage (380 V / 50 Hz) will be
applied to the inputs and damage the Troll Basic DuoFern.