Instructions

Item no.: 3520 11 64
VBD 701-1 (05.21)
DuoFern Switch Adapter 9472-1
Instruction manual
RADEMACHER
Geräte-Elektronik GmbH
Buschkamp 7
46414 Rhede (Germany)
1. This manual...
describes how to commission and operate the DuoFern Adapter Plug. Please
read this manual through completely and follow all the safety instructions.
This manual is part of the product. Please store it in an easily accessible
place. When passing the DuoFern Adapter Plug on to a third party, this
manual must be passed on as well.
1.1 Symbols used
Danger of fatal electric shock
Danger area / dangerous situation
i
Other useful
information
Do not use the DuoFern Adapter Plug to disconnect
a plugged in end unit.
Even when the DuoFern Adapter Plug is switched off,
the plugged in end unit is not completely disconnected
from the mains power supply.
The DuoFern Adapter Plug must be easily accessible in
the case of danger.
Switch off and disconnect the DuoFern Adapter Plug
before undertaking all work on the electrical end unit.
Improper use can lead to personal injury or property
damage.
Never use the DuoFern Radio System and its compo-
nents for the remote control of devices and systems
with increased safety-relevant requirements or where
there is an accident risk. Applications of this kind
require additional safety equipment.
Improper use can lead to serious property
damage.
Train all persons to use the DuoFern Adapter
Plug safely.
Never plug in several DuoFern Adapter Plugs in a row.
Never allow children to play with the device.
3. Intended use
Only use the DuoFern Adapter Plug for connecting and controlling electrical
appliances (e.g. lighting etc.) up to the maximum permissible switching
capacity, see “Technical specifications”.
Operating conditions
Use the DuoFern Adapter Plug only in dry rooms.
Use the DuoFern Adapter Plug only in 230 V / 50 Hz mains sockets
with earthed contacts.
i
Radio systems that transmit on the same frequency can
cause interference.
4. Improper use
Using the DuoFern Adapter Plug for any other purpose than previously
mentioned is not permissible.
5. Brief description
The DuoFern Adapter Plug can be used to integrate and control one
electrical appliance (e.g. lighting) within a DuoFern radio network. This
enables many of the functions provided by the DuoFern transmitter
(e.g. HomePilot® or DuoFern Manual Control) to be used.
5.1 Functions depending on the switching mode
The DuoFern Adapter Plug has two switching modes (unit and light mode)
that can be used to control electrical appliances. You can switch between
the two switching modes using an appropriate DuoFern transmitter (e.g.
HomePilot® etc.). To do so, please read the operating manual for the
respective DuoFern transmitter.
Factory setting = unit mode
Switching commands from a
DuoFern transmitter *
Reactions of the DuoFern
Adapter Plug in:
Unit
mode
Light
mode
UP ON OFF
STOP OFF OFF
DOWN OFF ON
ON ON ON
OFF OFF OFF
Automatic dawn function ON OFF
Automatic dusk function OFF ON
Sun function - OFF
* e.g. DuoFern Manual Transmitter Standard, HomePilot®,
DuoFern Wall Controller etc.
6. Installation
Activate log-on mode
Press and hold the button for 2 to 5 seconds. Release the button as soon
as the LED flashes green.*
Activate log-off mode
Press and hold the button for 5 to 10 seconds. The LED initially flashes green.
Release the button as soon as it flashes red.*
* The log-on and log-off mode respectively remain active for 120 seconds.
The log-on and log-off process has been successful if the LED lights up
continuously. The respective process has failed if the red LED lights up
continuously.
Resetting to the factory setting
Press and hold the button for 15 seconds. The LED initially flashes green,
then red. Release the button when the LED starts to light up red contin-
uously. The DuoFern Adapter Plug has now been returned to the default
setting on delivery.
8. Technical specifications
Supply voltage: 230 V AC, 50 Hz, 8 A max.
Max. switching capacity:
Ohmic load 1800 W, (e.g. light bulb)
Inductive load 200 W, (e.g. motor, fluorescent lamps)
Capacitive load 150 W, (e.g. lamps with LEDs)
Standby consumption: < 0.5 W
Protection class: II
Protection type: IP20 (only for use in dry rooms)
Transmission
frequency: 434.5 MHz
Transmission power: max. 10 mW
Radio range: up to 20 m, depending on the
building structure
Permissible ambient
conditions: 0 °C to 40 °C
DuoFern devices: max. 20 devices
Dimensions: 41 mm / depth = 73 mm
9. Simplified EU declaration of conformity
RADEMACHER Geräte-Elektronik GmbH, hereby declares that the
DuoFern Adapter Plug complies with the Directive 2014/53/EU
(Radio Equipment Directive). The full text of the EU declaration
of conformity is available on our website.
www.rademacher.de/ce
Warranty terms and conditions
You can find information about the warranty conditions of our products
on our homepage.
2. Safety instructions
There is a risk of fatal electric shock when touching live
electrical components.
Never open the device.
Do not use the DuoFern Adapter Plug should you
discover damage to the device. Contact our Customer
Service department in this event.
Never use the DuoFern Adapter Plug outside or in
damp rooms.
Overloading of the DuoFern Adapter Plug can lead to
the destruction of the device or a fire (e.g. caused by a
short circuit or overheating).
Observe the specifications for the maximum permissible
switching capacity in Technical specifications”.
7. Operation
Switch the connected device on / off
Press the button briefly.
i
Control via radio is only possible after logging on to a
DuoFern transmitter.
Operating button
incl. LEDs (green/red)
Subject to technical modifications, misprints and errors excepted. Illustrations not binding.
Insert the DuoFern Adapter Plug
into the mains socket. The DuoFern
Adapter Plug is now ready for use.
Then plug in the desired
end unit.
service.en@rademacher.de
Tel.: +49 2872 933 175