EN Operating instructions DuoFern Connect actuator..............................25 Item no. 3500 08 64 VBD 586-1 (05.
i Dear Customers... EN ...with your purchase of this DuoFern Connect actuator, you have decided for a quality product manufactured by RADEMACHER. We would like to thank you for your confidence. This product has been designed in an effort to the greatest possible ease of operation. With uncompromising quality requirements, after extensive test series, we are proud to present this innovative product to you. All of our highly qualified staff at RADEMACHER stand behind this product. i These instructions...
i Contents EN i Dear Customers.................................................................................... 26 i These instructions................................................................................ 26 1. Key to Symbols...................................................................................... 28 2. General safety instructions............................................................... 29 3. Correct usage..........................................................
i 1. Key to Symbols EN Danger of fatal electric shock. This sign warns of danger when working on electrical connections, components etc. It requires that safety precautions be taken to protect the health and life of the person concerned. This concerns your safety. Please pay particular attention to and carefully follow all instructions with this symbol. NOTE/IMPORTANT/ATTENTION This is to draw your attention to information which works is important to ensure trouble-free operation.
i 2. General safety instructions EN All work performed on electrical equipment is associated with a risk of electric shock and electrocution. ◆◆ The electrical connection and all work on electrical systems must only be carried out by a qualified electrician (see chapter 10. - 10.2). ◆◆ Carry out all installation and connection work only in an isolated, deenergised state. The use of defective equipment can lead to personal injury and damage to property (electric shocks, short circuiting).
i 3. Correct usage EN Only use the DuoFern Connect actuator for the control of: ◆◆ Roller shutters and Sun shading systems ◆◆ Blinds and external Venetian blinds Operating conditions ◆◆ The installation and operation of the DuoFern radio system and its components is only permitted for those systems and devices where a malfunction in the transmitter or receiver would not cause a danger to persons or property or where this risk is already covered by other safety equipment.
i 5. General view EN Drive Status LED Type plate Safety clip Fastening lug Mains (230 V / 50 Hz) SET Magnet Connect surface / Disconnect surface / NOTE Log on/off to/from DuoFern transmitters, s. page 42.
i 6. Brief description EN The DuoFern Connect actuator can be used to equip drives for blinds, external Venetian blinds and roller shutters with DuoFern radio technology. As soon as you integrate your DuoFern Connect actuator into a DuoFern radio network, you can make use of many functions offered by the corresponding DuoFern controllers in combination with the connected drive. The DuoFern actuators and transmitters must be connected to the DuoFern network.
i 7. Functional characteristics EN DuoFern HomePilot DuoFern environmental sensor DuoFern manual central operating unit * WR ConfigTool with DuoFern manual central operating unit RolloTron Comfort DuoFern / Troll Comfort DuoFern DuoFern Standard manual transmitter DuoFern Wall controller Function Valuerange Up / Stop / Down Factorysetting - 2. Direct drive to a %-Position 0 % - 100 % - 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24.
i 7. Functional characteristics EN DuoFern HomePilot DuoFern environmental sensor DuoFern manual central operating unit * WR ConfigTool with DuoFern manual central operating unit RolloTron Comfort DuoFern / Troll Comfort DuoFern DuoFern Standard manual transmitter DuoFern Wall controller Function 25. Reset via radio (3-stage) 26. 27. 28. 29. 30. 31. 32. 33. 34.
i 8. Description of the configurable parameters EN The most important configurable parameters are described here for carrying out the basic configuration (installation) of the actuator. Running time: This sets the time which the drive requires for a complete lift of the shutters. In order to record the time, please move the shutters down to the lower limit position and then move them to the upper limit position. Record the time as precisely as possible during the lifting process.
i 8. Description of the configurable parameters EN Automatic tilting in sun and ventilation positions: If the respective parameter is activated, the slats will be automatically tilted after moving to the corresponding sun or ventilation position and will be shifted to the default slat position. This function can be configured separately for the corresponding sun and ventilation position.
i 8. Description of the configurable parameter EN Motor reaction time (dead time) Here you can set the time required by the motor after switching on before it starts up. In order to do so, observe the motor type and specifications given by the respective motor manufacturer. For motors with mechanical end point settings, the reaction time is extremely short – in this case the “off” setting (0 ms) is recommended.
i 9. Installation / Dismantling EN The DuoFern Connect actuator is intended for surface-mounting. ATTENTION In order to ensure optimal operation, the DuoFern Connect actuator should not be installed on a metallic base or near metal objects. i 9.1 Installation 1. Switch off the mains. 2. Connect DuoFern Connect actuator in accordance with chapter 10. - 10.2. 3. Mount the DuoFern Connect actuator. 4. Reconnect the mains power. 5.
i 10. Electrical connection - Safety instructions EN There is a risk of fatal electric shocks. ◆◆ The electrical connection and all work on electrical systems must only be carried out by a qualified electrician in accordance with the connection instructions in these operating instructions. ◆◆ Carry out all installation and connection work only in an isolated, deenergised state. ◆◆ Disconnect all phases of the mains power supply cable and secure it to prevent re-connection.
i 10.1 Electrical connection EN 1. Switch off the mains power and secure it to prevent any reactivation. 2. Connect the wires in accordance with the specifications given on the type plate and in accordance with the wiring diagram on page 41. Unintentional removal of the connecting cable during operation of the equipment can lead to life-threatening situations due to electric shocks or short circuits. Secure both connecting cables against removal with the help of the tension relief mechanism. 3.
10.2 Wiring diagram EN 3 L2 IN N 1 2 1 Art.-Nr. : OUT N DuoFern 3 Mains 230 V / 50 Hz) 230V / 50 Hz 434,5 MHz Standby < 0,5 W IP 54 5 (2) A µ Drive Drive 3 = ▼ (black / brown) PE = (green / yellow) 2 = ▲ (brown) 1 = N (blue) Mains (230 V / 50 Hz) 3 L2 IN N 1 Art.-Nr.
i 11. Logging DuoFern transmitters on/off EN You must assign every required DuoFern transmitter to the DuoFern Connect actuator in order that the actuator can be controlled with a DuoFern transmitter. You can assign max. 20 DuoFern transmitters (e. g. RolloTron Pro Comfort DuoFern) to the actuator. Additional informations about logging on can be obtained from the log-on matrix on our website under www.rademacher.de. 1.
i 11. Logging DuoFern transmitters on/off EN 4. If log-on/log-off is successful, the status LED will light up green and the drive starts up briefly by way of confirmation. 5. Register the next DuoFern transmitter. In order to do so, repeat steps 1 to 3, or else terminate registration. NOTE The status LED lights up red if the registration process fails, for example if: ◆◆ 20 DuoFern transmitters have already been registered. ◆◆ an attempt is made to register an unsuitable device (e. g.
i 13. Erase data (reset) EN 1. Hold the SET magnets provided against the “Disconnect” surface until the status LED lights up continuously red. 2. All settings will be erased and reset to the default factory setting. 3. All of the registered DuoFern transmitters are automatically logged-off. 4. Subsequently, the DuoFern Connect actuator will be reset to its original supplied state.
i 14. Technical data EN Supply voltage: 230 V / 50 Hz Standby consumption: < 0,5 W Switching load: max. 5 A ohmic load max. 2 A inductive load Output: 1 x tubular motor Range: - in a building: approx. 30 m (depending on contruction) - outside: approx. 100 m i Transmission frequency: 434,5 MHz Maximum number: - DuoFern transmitters: 20 Permissible ambient temperature: - 25 °C to + 55°C Protection type: IP54 Dimensions: 123,5 x 33,5 x 26,5 mm (L x W x H) 15.
i 16. Accessories EN Plug-ans socket connections (IP54, max 16 A) STAK3 N STASI 3 colour item no. Coupling STAK3 N: (black) 7000 00 83 Plug STAS3 N, incl.
i 17. Warranty conditions EN RADEMACHER Geräte-Elektronik GmbH provides a 24-month warranty for new systems that have been installed in compliance with the installation instructions. All construction faults, material defects and manufacturing defects are covered by the warranty.
RADEMACHER Geräte-Elektronik GmbH & Co. KG Buschkamp 7 46414 Rhede (Germany) info@rademacher.de www.rademacher.de Service: Hotline 01807 933-171* Telefax +49 2872 933-253 service@rademacher.de * 30 seconds free of charge, subsequently 14 cents / minute from German fixed line networks and max. 42 cents / minute from German cellular networks. Subject to technical modifications, misprints and errors excepted. Figures subject to change.