Instructions
48
EN
Menu overview / 1
.
1 Actuators
Name: End points
Function: Set the upper and lower end point for the currently selected drive.
Proceed as follows:
1.
/ Move the roller shutters to the centre position.
2. Call up the menu "
1
.
1
.
2
.
A".
3.
/ Press and hold the required key; the roller
shutter moves up or down..
4. Release the button as soon as the desired end point is reached.
IMPORTANT
Release the key promptly and never allow it to extend beyond
the respective limit stop. Failure to do so can cause overloading
and may damage the drive.
5. The roller shutter stops and the upper / lower end point is stored.
Adjusting the end points:
6. Repeat the above steps.
1
.
1
.
2
.
A
DescriptionMenu
Description
Menu
Name: Software version
Function: Displays the software version for the currently selected actuator.
1
.
1
.
2
.
b