1 Actuators
Name: Stairway / impulse function
Function: Switch the stairway / impulse function on / off for the selected actuator.
Additional configuration options are available with the
"WR ConfigTool" software.
If the stairway counter is set very low, then the actuator will generate
a corresponding impulse.
1
.
1
.
2
.
4
DescriptionMenu
Name: Running time
Function: Configures the running time for opening a roller shutter.
If the roller shutter drive is configured to move to specific positions
(e.g. position of the sun / ventilation position), then the running
time for opening and closing the roller shutter should be determined
and entered in advance.
Proceed as follows:
1. Measure the opening time of the roller shutter.
2. Select the actuator which is connected to the roller shutter drive.
3. Enter the measured opening time plus 2 seconds.
1
.
1
.
2
.
5
DescriptionMenu
Name: Remote log on / off
Function: Activate connect / disconnect mode for an actuator.
Subsequently, you can connect a DuoFern flush-mounted actuator
with another DuoFern manual transmitter, for example.
Connect
Quit connect / disconnect mode
Disconnect
1
.
1
.
2
.
3