End point setting
You can use this function to subsequently set or correct the end points of Rademacher electronic tubular motors from the year
2000 onwards.
Conditions for the end point setting:
The end point setting can only be performed if only one device (actuator) is logged on to the selected group. If more
than one participant is logged on to the selected group, the function is blocked.
The end point setting is possible for DuoFern radio tubular motors.
The end point setting is possible for RADEMACHER electronic tubular motors from the year 2000 onwards that are con-
trolled with a correctly installed DuoFern actuator.
The end point setting is not possible for tubular motors connected in parallel.
The function is automatically cancelled if no button is pressed for approx. 30 seconds.
Select the desired DuoFern end
unit.
2 x / second Activate the “End point setting” function.
In order to do so, press the Disconnect button twice in
short succession within one second.
or