Instructions
Table Of Contents
- 1. This manual...
- 1.1 How to use this manual
- 2. Hazard symbols
- 2.1 Symbols and depictions used
- 3. Safety instructions
- 3.1 Intended use
- 4. Included in delivery
- 5. General view
- 5.1 Operating buttons
- 5.2 Display and its symbols
- 6. Product description
- 7. Technical specifications
- 8. Installation
- 8.1 Installation sequence
- 9. Menu overview
- 10. Menu 1 - Configuring the sun function
- 11. Menu 2 - Configuring the wind function
- 12. Menu 8 - Service functions
- 12.1 Menu 8.1 - Sun test function
- 12.2 Menu 8.1 - Wind test function
- 12.3 Menu 8.2 - Rotation direction test / change of rotation direction
- 12.4 Menu 8.3 - Checking the battery status
- 12.5 Menu 8.0 - Viewing the software version
- 13. Menu 9 - Logging DuoFern devices on/off
- 13.1 Logging on devices
- 13.2 Logging off devices
- 13.3 Clear-up
- 13.4 Deleting all DuoFern devices
- 14. Reset (factory settings)
- 15. Cleaning and care
- 16. Simplified EU declaration of conformity
36
EN
14. Reset (factory settings)
This function can be used to completely reset the DuoFern Sun/Wind
Sensor to the factory settings.
All previous settings and logged-on DuoFern devices are deleted.
1.
OK
M
Press any button to turn
on the display.
2.
OKOKOK
MMM
4 sec. Press and hold all 4 buttons simultaneously.
Then all data is reset to the factory settings:
Set limits:
- Sun 60 klux
- Wind 18 km/h
Logged-on
DuoFern devices: none
2.1 To confirm this, all symbols and segments are
shown on the display.
3. Release the four buttons again.
The software version is then briefly displayed.
The standard display then appears again, see
point 1 above.
i