7. Technical specifications
Measuring ranges
Sun sensor: 1 klux to 99 klux / off
> Sun detected after: 10 minutes
> Shade detected after: 20 minutes
Wind sensor: 10 km/h to 99 km/h / off
General information
Battery power reserve: 24 hours
Permissible ambient
temperature:
-10 °C to 60 °C
Protection type: IP44
Dimensions (L x W x H): 255 x 122 x 75 mm
DuoFern radio technology
Transmission frequency: 434.5 MHz
Transmission power: max. 10 mW
Range:
Indoors up to 20 m
Outdoors up to 50 m
Maximum number of
DuoFern devices:
3