Specifications

Installation and Operation Manual Chapter 6 Diagnostics and Troubleshooting
ASMi-54 Ver. 1.0 Displaying Interface Statistics 6-13
ASMi-54
Main Menu > Monitoring > Physical Ports > SHDSL > Statistics >
PME Statistics > Current Interval
PME (Physical Medium Entity) Number (1)
PCS (Physical Coding Sublayer) Number (1)
ES (0)
UAS (0)
SES (0)
LOSWS (0)
CRC Anomalies (0)
Elapsed Time (150)
F-Forwards ; B-backwards
ESC-Previous menu; !-Main Menu; &-Exit
Figure 6-17. SHDSL PME Current Interval Statistics Screen
Table 6-9. SHDSL PME Current Interval Statistics
Parameter Description
PME (Physical Medium
Entity) Number
The selected SHDSL PME number.
PCS (Physical Coding
Sublayer) Number
The SHDSL PCS number to which the PME line belongs.
ES The number ofof Errored Seconds (ES) in the current 15-
minute interval.
UAS The number of Unavailable Seconds (UAS) in the current
15-minute interval.
SES The number of Severely Errored Seconds (SES) in the
current 15-minute interval.
LOSWS The number of Count of Loss of Sync Word (LOSW) Seconds
in the current 15-minute interval.
CRC Anomalies The number of CRC anomalies in the current 15-minute
interval.
Elapsed Time The total elapsed seconds in the current 15-minute interval.