Specifications
Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring for Operation ASMi-54 Ver. 1.0
Configuring the SHDSL Ports
This section includes procedures for configuring the SHDSL PCS ports, configuring
the SHDSL PME ports, and setting the clock source.
Configuring the SHDSL PCS Ports
To configure SHDSL PCS ports:
1. Select Main Menu > Configuration > Physical Layer.
The Physical Layer screen appears (see
Figure 4-14
).
2. Select SHDSL.
The SHDSL PCS Port Configuration screen appears (see
Figure 4-16
). The
parameters are described in
Table 4-3
.
ASMi-54
Main Menu > Configuration > Physical Layer > SHDSL
PCS (Physical Coding Sublayer) (1)
Administrative Status (Up)
Power Backoff (Disable)
1. Clock Source (RX Clock: STU-R)
2. PME Configuration >
>
F-Forward
ESC-Previous menu; !-Main menu; &-Exit
Figure 4-16. SHDSL PCS Port Configuration Screen
Table 4-3. SHDSL PCS Port Configuration Parameters
Parameter Possible Values Remarks
PCS (Physical
Coding
Sublayer)
1 Index of the SHDSL PCS.
Default: 1
Administrative
Status
Up
Down
Administrative status of the SHDSL PCS.
Default: Up
Power Backoff Disable The power backoff mode.
Default: Disable
Note: This parameter is Read Only and cannot be configured.
Clock Source Internal: STU-C
RX Clock: STU-R
The source clock determines SHDSL mode (STU-C or STU-R). If source
clock is receive (RX), source port is the first connected SHDSL line.
Default: RX Clock: STU-R