Specifications
Chapter 2 Installation and Setup Installation and Operation Manual
2-4 Connecting to Power ASMi-54 Ver. 1.0
Connecting to the SHDSL Equipment
The SHDSL interfaces terminate in an 8-pin RJ-45 connector.
To connect the SHDSL interface:
• Connect an SHDSL line to an RJ-45 connector designated SHDSL (1,2,3,4).
Connecting to an ASCII Terminal
To connect the ASCII terminal:
• Connect the unit's CONTROL port to an ASCII terminal or an out-of-band
management station with a straight RS-232 cable.
2.7 Connecting to Power
ASMi-54 is equipped with a dual input AC/DC power supply. AC or DC power is
supplied to ASMi-54 via a standard 3-prong power input connector on the rear
panel (see
Figure 2-1
).
Before connecting this unit to a power source and connecting or disconnecting
any other cable, the protective earth terminals of this unit must be connected to
the protective ground conductor of the mains (AC or DC) power cord. If you are
using an extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or outside the
instrument) or disconnecting of the protective earth terminal can make this unit
dangerous. Intentional interruption is prohibited.
Connecting AC Power
AC power should be supplied through the 1.5m (5 ft) standard power cable
terminated by a standard 3-prong plug. The cable is provided with the unit.
To connect AC power:
1. Connect the power cable to the power connector on the ASMi-54 rear panel.
2. Connect the power cable to the mains outlet.
The unit turns on automatically upon connection to the mains.
Connecting DC Power
DC power is supplied to ASMi-54 via a compatible AC/DC plug for attaching DC
power supply lines.
To connect DC power:
• Refer to the DC power supply connection supplement. Refer to the
Handling
Energized Products
section at the front of this manual for safety instructions.
Warning