Specifications
Chapter 1 Introduction Installation and Operation Manual
1-4 Overview ASMi-54 Ver. 1.0
Access to the ASMi-54 software can be limited to the ASCII terminal and
ConfiguRAD management by disabling the Telnet access.
The following functions are supported by the internal management software:
• Local terminal, Telnet server, SNMP (V1), WEB server (ConfiguRAD)
ConfiguRAD is RAD’s Web-based element management system for remote
device configuration and maintenance. ConfiguRAD is embedded in the unit
and can be accessed from any standard Web browser.
• RADview-Lite
RADview-Lite is RAD’s SNMP-based element management software, providing
SNMP traps, status polling, and configuration download. Remote element
management is available in either through the ConfiguRAD or Telnet.
• Inband and out-of-band management with/without dedicated management
VLAN
• Ping and Trace Routes
• Remote software and configuration download / upload via TFTP
• DHCP client to obtain IP address, mask and default gateway
• Viewing system information
• Modifying configuration and mode of operation, including setting system
default values and resetting the unit
• Monitoring performance
• Initiating connectivity tests
• Upgrading software.
Timing
ASMi-54 operates with the following clock sources:
• Internal clock source, derived from the modem as a CO unit
• Received clock source, derived from the DSL line on a CPE unit.
Diagnostics
Real-time alarms provide information on the system status, indicating
management failure, synchronization loss, and other conditions.
ASMi-54 also supports performance monitoring.
Event Log File
The Event Log file includes entries at the system and Ethernet levels.
Statistics
ASMi-54 provides statistics and counter capabilities in the physical Ethernet and
SHDSL level.