Specifications
Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-10 Troubleshooting ASMi-54C LRS-102 Ver. 2.0
Parameter Description
Tx Multicast Frames Total number of good multicast frames transmitted by the corresponding
Ethernet port
Tx Broadcast Frames Total number of good broadcast frames transmitted by the corresponding
Ethernet port
4.2 Handling Alarms
Table
4-9
lists the specific alarm messages that may generated by LRS-102 for
ASMi-54C modules, and explains their interpretation. The messages are listed in
ascending order of their codes.
For other alarm messages, refer to the
LRS-102 Installation and Operation
Manual
.
Table
4-9. ASMi-54C Specific Alarms
Code Message Type
Default
Severity
Interpretation
023 RESET OCCURRED Event The module installed in the specified slot has been
reset automatically
645 SHDSL LOOP ATTENUATION
ERROR
Minor Loop attenuation has exceeded the alarm
threshold
646 SHDSL SNR MARGIN ERROR Minor Signal-to-noise margin has exceeded the alarm
threshold
647 SHDSL LOSW FAILURE Minor Loss of Sync Word is detected
648 SHDSL PSD NOT COMPATIBLE Minor Mismatch between PSD mode selected by the user
and PSD mode used by the line
651 SHDSL CRC6 ERROR Event CRC errors are detected
652 SHDSL SYNC LOSS Major SHDSL line is not synchronized
4.3 Troubleshooting
In case a problem occurs, check the displayed alarm messages and refer to
Table
4-9
and to the
LRS-102 Installation and Operation Manual
for their
interpretation.