Specifications
Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-6 Monitoring Performance ASMi-54C LRS-102 Ver. 2.0
3. Select the desired Line.
4. Select Statistics > Select Interval (24 hours).
5. Select the desired interval, by selecting 24-Hour Interval and pressing
<Enter>: you can then enter the desired interval number, 1 to 7.
6. After pressing <Enter>, the data displayed on the screen is updated in
accordance with your selection.
The displayed parameters are explained in
Table
4-5
.
Table
4-5. SHDSL Line Statistics Parameters – Selected 24-Hour Interval
Parameter Description
ES Displays the total number of SHDSL errored seconds (ES) in the selected 24-hour
interval
UAS Displays the total number of SHDSL unavailable seconds (UAS) in the selected 24-hour
interval
SES Displays the total number of SHDSL severely errored seconds (SES) in the selected
24-hour interval
LOSWS Displays the total number of SHDSL LOSW seconds (LOSWS) in the selected 24-hour
interval
CRC Anomalies Displays the total number of CRC anomalies in the selected 24-hour interval
24-Hour Interval Used to select the desired 24-hour interval (the available range is displayed in the 24H
Intervals field of the Current (15 min) statistics screen – see
Table
4-2
)
Monitoring Ethernet Ports
The Ethernet port physical layer performance monitoring data includes:
• Status data for the port.
• Statistics data. Statistics can be displayed only for enabled ports: if the
Ethernet port is not enabled, its monitoring display is empty.
Displaying Ethernet Port Status
³ To display status data for an Ethernet port:
1. Navigate to the Monitoring > Physical Layer > IO > Ethernet screen of the
desired module, and select the desired Ethernet port, ETH 1 or ETH 2.
2. On the Ethernet port screen, select Status. The Ethernet port status
parameters are explained in
Table
4-6
.
3. For an Ethernet port with optical interface, you can also display information
and status data for the SFP serving the port: select SFP Status on the
corresponding Ethernet port Status screen. The SFP status parameters are
explained in
Table
4-7
.
When no SFP is installed, or the data cannot be read, you will see Missing for the
Connector Type, and the other fields display zero.
Note