Specifications

Chapter 3 Configuration Installation and Operation Manual
3-12 Configuring Physical Layer Parameters of Ethernet Ports ASMi-54C LRS-102 Ver. 2.0
Parameter Function Values
Lines Used to select the number of lines
in the PCS group.
See the available selections in
Table
3-4
.
This parameter is displayed only
when TC Layer = 64/65-Octet
For single line: the line with the same index as the PCS.
For multiple lines: the list of lines (2 or 4), separated by
commas (see range in
Table
3-4
)
3.6 Configuring Physical Layer Parameters of
Ethernet Ports
³ To configure the parameters for the ASMi-54C Ethernet ports:
1. Navigate to the Configuration > Physical Layer > I/O screen, and then select
the module I/O slot.
2. Select the Ethernet option.
You will see the configuration screen for the first Ethernet port (the port
with the lowest index number). Scroll using F and B to reach the desired
port, or use the Port field to enter manually the desired port number, 1
or 2.
Alternatively, first preconfigure all the ports with the same basic
parameters (All Ports option), and then sequentially select each port and
change its parameters as required. You will see the configuration screen
for the selected line.
Table
3-6
describes the Ethernet port physical layer configuration parameters.
Table
3-6. Ethernet Port Physical Layer Configuration Parameters
Parameter Function Values
Administrative
Status
Used to enable/disable the flow of
traffic through the selected Ethernet
port
DOWN – The flow of traffic is disabled. This state
should be selected as long as the configuration of
the corresponding port has not yet been completed,
or when it is necessary to stop traffic flow through
the port.
UP – The flow of traffic is enabled.
Default: DOWN
Name Used to enter a logical name for the
selected Ethernet port
Up to 25 alphanumeric characters.
Default: Empty string