Specifications
Chapter 3 Configuration Installation and Operation Manual
3-2 ASMi-54C Configuration Sequence ASMi-54C LRS-102 Ver. 2.0
Parameter Description Factory Default Value
Transmission Mode Regional-dependent parameters set
Annex B/G
Line Probe Line probing per ITU-T Rec. G.991.2
Enable
Payload Rate Line payload rate, in kbps
192
Current Margin (dB) Measured noise level
0
Worst Margin (dB) Target margin for signal-to-noise ratio
Disable
Loop Attenuation
Threshold (dB)
Generation of an alarm in case the attenuation
measured on the SHDSL line exceeds a selected
threshold value
0
SNR Margin Threshold
(dB)
Generation of an alarm in case the attenuation
measured on the SHDSL line exceeds a selected SNR
margin threshold
0
PCS Parameters
PCS PCS index number 1
Administrative Status PCS administrative status Down
Name PCS logical name Empty string
Lines Lines in the PCS group 1
Ethernet Port Physical Layer Parameters
Port Ethernet port index number 1
Administrative Status Ethernet port administrative status Down
Name Ethernet port logical name Empty string
Auto Negotiation Ethernet port autonegotiation mode Enable
Max. Capability
Advertised
Highest traffic handling capability advertised when
autonegotiation is enabled
100Mbps full duplex
Speed & Duplex Ethernet port data rate and operating mode when
autonegotiation is disabled
100Mbps full duplex
Flow Control Ethernet port flow control or back pressure Disable
3.3 ASMi-54C Configuration Sequence
Outline of Configuration Sequence
Make sure to plan ahead the configuration sequence, because LRS-102 databases
can be updated only after correctly completing the configuration activities: any
sanity error will prevent saving the changes to the database being modified. For
example, a common cause of sanity errors that may prevent updating the
database is that timeslots have to be assigned to ports of other modules that will
be served by the ASMi-54C ports.