Specifications

Table Of Contents
Installation and Operation Manual Appendix C List of Parameters
ASMi-52CD Ver. 1.0 Configure Transmission Parameters C-7
Parameter Type Use Value Indication
TS Write Assigning each timeslot to
carry data
DATA
NOT_
CONNECT
TS0 may be looped or
transparent:
Looped: TS0 is sent back to
the E1 interface, when
operating opposite remote
units with a serial data
interface.
Transparent: TS0 is
transmitted to the remote
modem.
With G732S transparent
framing, TS0 is always
transparent and TS16 is
always connected.
When operating opposite an
ASMi-52CD with V.35
interface, assign at least six
timeslots, including timeslot
0 to carry data.
Table C-4. Modem Setup: Line Parameters
Parameter Type Use Value Indication
ASMi-52CD ASMi-52CD MODEM NAME Read Identifying the modem
type whose status is being
viewed or modified
ASMi-52 Standalone ASMi-52 modem
DEFINE MODEM
PORT NUMBER
Write Selecting the number of
the port to be configured
Default is selected port
MODEM STATUS Read Viewing the modem
configuration control
status
MASTER
PERMANENT
N/A
Enable Enable transmitted power
backoff
POWER BACKOFF Write Determining whether to
use the transmitted power
backoff
Disable Disable transmitted power
backoff
Integer
between -10
and 10
Selected Snext margin value
SNEXT MARGIN Write Selecting the minimum
desired target margin with
a worst case self next
noise model given current
loop insertion (49 SHDSL
next is considered the
worst case).
Available only if the rate
adaptation is enabled (see
line probing configuration
below).
Disable Disable Snext margin.
Allows the use of all line rates,
regardless of line condition