Specifications
Table Of Contents
- Front Matter
- Quick Start Guide
- Contents
- Chapter 1 Introduction
- Chapter 2 Installation and Setup
- Chapter 3 Operation
- Chapter 4 Configuration
- Chapter 5 Troubleshooting and Diagnostics
- Appendix A Pinouts
- Appendix B Memory and Download
- Appendix C List of Parameters
- Appendix D IR-ETH Ethernet Card
- Appendix E IR-ETH/Q Ethernet Card
- Appendix F IR-ETH/QN Ethernet/Fast Ethernet Card
- Appendix G IR-IP Interface Card
- G.1 Introduction
- G.2 Technical Specifications
- G.3 Installation and Operation
- G.4 IR-IP Management Subsystem, General
- G.5 Performing Preliminary Configuration
- G.6 IR-IP Management Utility
- G.7 Quick Setup Menu
- G.8 Management Access Menu
- G.9 Advanced Setup Menu
- G.10 Device Control Menu
- G.11 View Menu
- G.12 Diagnostic Tool (Ping Terminal) Menu
- Back Matter

Installation and Operation Manual Appendix C List of Parameters
ASMi-52CD Ver. 1.0 Configure Transmission Parameters C-5
Table C-2. Modem Setup
Parameter Type Use Value Indication
ASMi-52CD Master ASMi-52CD MODEM NAME Read Identifying the modem
type whose status is being
viewed or modified
ASMi-52 Standalone ASMi-52 modem
MODEM STATUS Read Viewing the modem
configuration control
status
MASTER
PERMANENT
N/A
DATA RATE Write Setting data rate
transmitted between the
modems
2 wire: 64, 128, 192, 256, 320, 384, 448, 512,
576, 640, 704, 768, 832, 896, 960, 1024,
1088, 1152, 1216, 1280, 1344, 1408, 1472,
1536, 1600, 1664, 1728, 1792, 1856, 1920,
1984, 2048, 2304 kbps
4 wire: 128, 256, 384, 512, 640, 768, 896,
1024, 1152, 1280, 1408, 1536, 1664, 1792,
1920, 2048, 4608 kbps
Internal Clock is supplied by internal
oscillator
CLOCK SOURCE
LOCAL/REMOTE
Write Setting timing mode of
local and remote modems
System External source derived from
LRS-24 that supplied the
system clock to all the hub’s
modems.
(2.048 MHz)
EXT SOURCE Write Setting one of the ports as
external clock source.
E1 interface only
Modem #1
Modem #2
DCE Clock for indicated port
connection is internal
#n PORT Write Selecting clock for an
indicated port (n) as
external or internal
DCE-EXT Clock for indicated port
connection is external
FILTER The internal bridge of the
channel is enabled, and filters
the traffic sent to the remote
end.
TRANS The internal bridge of the
channel is disabled, and the
Ethernet traffic is transferred
transparently.
BRIDGING Write Selecting Ethernet traffic
control function of the
modem. For a channel
with serial data interface,
this field always shows
N/A, and cannot be
changed
N/A