Specifications

Table Of Contents
Chapter 5 Troubleshooting and Diagnostics Installation and Operation Manual
5-6 Alarms ASMi-52CD Ver. 1.0
Viewing Alarm Messages from an ASCII Terminal
The MODEM ALARM STATUS screen (
Figure 5-4
) enables viewing messages stored
in the alarm buffer of ASMi-52CD and remote modems. The screen also shows
synchronization loss and DTE loopback signaling states.
To view the ASMi-52CD alarms:
1. From the Main menu, select Alarm Status.
2. Select the ASMi-52CD slot and define the modem which alarms you intend to
view.
The MODEM ALARM STATUS screen shown in
Figure 5-4
appears. This
screen displays the general alarms of ASMi-52CD.
3. To view E1 alarms, change Next Alarm (E1) value to ON and press <Tab> to
display next alarm screen (available only for ASMi-52CD/4 with E1 interface).
The screen shown in
Figure 5-5
appears.
4. To view SHDSL line alarms, change Next Alarm (LINE) value to ON and press
<Tab>.
The screen shown in
Figure 5-6
appears.
MODEM ALARM STATUS
MODEM NAME : ASMi-52CD
DEFINE MODEM PORT NUMBER : 1
SELECT MODEM : MODEM 1 LOCAL
LINE DISCONNECT : OFF
REMOTE MODEM POWER OFF : OFF STUFFING OVERFLOW EXC : OFF
TRANSMIT CARRIER : OFF NVRAM FAILED : OFF
RECEIVE CARRIER : OFF PROP PROTOCOL FAILED
LLB BY DTE : OFF SOFTWARE DWL IN PROCESS : OFF
RLB BY DTE : OFF INCOMPATIBLE CONNECTORS : OFF
SYNC LOSS A : ON SYNC LOSS B : ON
CRC6 ERR EXC A : OFF CRC6 ERR EXC B : OFF
CONFIGURATION MISMATCH : OFF PHASOR OVERFLOW EXC : OFF
ILLEGAL EXTERNAL CLOCK SOURCE : OFF WRONG CONNECTION : OFF
NO MANAGEMENT LINK : OFF XILINK FAILED : OFF
NO MODEM PORT (IR) : OFF LAN NOT CONNECTED : OFF
NO FIBER INTERFACE : OFF NO EXT CLK INPUT : OFF
IR RATE MISMATCH : OFF ILL. CLK-ERR : OFF
SELF TEST FAILED : OFF OLD REM VERSION : OFF
MINOR ALARM-AIS-ELEC : OFF AIS-OPT : OFF
MAJOR ALARM-LINE DISCON.-ELEC : OFF LINE DISCON. – OPT : OFF
NEXT ALARMS(E1) : NO NEXT ALARMS(SHDSL) : NO
Figure 5-4. Modem Alarms Status Screen