Specifications
Table Of Contents
- Front Matter
- Quick Start Guide
- Contents
- Chapter 1 Introduction
- Chapter 2 Installation and Setup
- Chapter 3 Operation
- Chapter 4 Configuration
- Chapter 5 Troubleshooting and Diagnostics
- Appendix A Pinouts
- Appendix B Memory and Download
- Appendix C List of Parameters
- Appendix D IR-ETH Ethernet Card
- Appendix E IR-ETH/Q Ethernet Card
- Appendix F IR-ETH/QN Ethernet/Fast Ethernet Card
- Appendix G IR-IP Interface Card
- G.1 Introduction
- G.2 Technical Specifications
- G.3 Installation and Operation
- G.4 IR-IP Management Subsystem, General
- G.5 Performing Preliminary Configuration
- G.6 IR-IP Management Utility
- G.7 Quick Setup Menu
- G.8 Management Access Menu
- G.9 Advanced Setup Menu
- G.10 Device Control Menu
- G.11 View Menu
- G.12 Diagnostic Tool (Ping Terminal) Menu
- Back Matter

Installation and Operation Manual Chapter 2 Installation and Setup
ASMi-52CD Ver. 1.0 Connecting the Interface Cables 2-7
2.5 Connecting the Interface Cables
ASMi-52CD is connected to the line and DTE via the interface module. Identify the
necessary cables for the interface module you have installed and prepare the line
and DTE cables. Refer to
Table 2-1
or
Table 2-2
to prepare the line cable. Refer to
Appendix A
for information on adapter cables and pin assignments for the DTE
cables.
Connecting the Line and DTE
To connect the line and DTE cables to the interface module:
1. Connect the line and DTE cables to the appropriate interface module
connectors.
2. Use the side screws of the DTE cable connector to fasten the cable to the
interface module DTE connector.
Table 2-1. Pin Assignment of Line Connector for ASMi-52CD
Pins ID Function Direction
4, 5 LINE Bidirectional line Input/Output
1, 2, 3, 6, 7, 8 – Not connected –
Table 2-2. Pin Assignment of Line Connector for ASMi-52CD/4
Pins ID Function Direction
1, 2, 4, 5 LINE Bidirectional line Input/Output