Tus neeg siv phau ntawv

B-RAD Select
USER MANUAL
Page 20 New World Technologies Inc.
V2022.06.20
To advance the menu items:
Hold the button and press the button to advance to the
next menu item (illustrated in Figure 5.1-2).
Hold the button and press the button to return to the
previous menu item.
To view the title of a menu item, press the button for 3
seconds. The title is displayed for as long as the button is held.
Note that showing the menu title will also reset the menu value
to the previously saved value if the value was changed.
Any changed values will be saved when the menu is advanced.
A modified value is indicated by the two dots on the LED
display blinking quickly. When the value is saved, the LED dots
blink more slowly.
Figure 5.1-2: Menu Advance Function
5.2 Table of Calibration Menus
The order and function of the menus in Calibration Mode are outlined in Table 5.2 below.
Note: Only CPhi, CPLo, and the CAL points are available after the first cycle through the menu. The first 4 options become
available when the calibration menu is opened again.
Menu Title Description of Function
Tool Gearbox Model – View the current tool model. The models are shown in Table 5.2.2 below.
Ser Tool Serial Number. Can only be changed by factory.
Lo Minimum Torque Limit – Set up to 100% higher than default. Can only be changed by factory.
Hi Maximum Torque Limit – Set down to 50% lower than rated maximum. Can only be changed by factory.
CPhi Calibration Point High – Sets the maximum tool output for Calibration. The value may range between 10 and 990.
CPLo Calibration Point Low – Sets the minimum tool output for Calibration. The value may range between 10 and 990.
CAL1, CAL2, …
CAL6
Tool Calibration Points – Calibrates output torque at six evenly spaced points over the output range.
Table 5.2: Calibration Menu Titles and Functions
5.3 Table of Tool Models
The first Menu in Calibration Mode is the Gearbox Select Menu. Table 5.3 shows which Gearbox setting in the
Menu corresponds to the desired tool model.
Gearbox Designator Tool Model
G00 Default: 10 – 990
G01 40 – 200 ft·lb
G02 50 – 270 N·m
G03 70 – 350 ft·lb
G04 100 – 470 N·m
G05 120 – 500 ft·lb
G06 170 – 700 N·m
G07 200 – 1000 ft·lb
G08 300 – 1400 N·m
G09 300 – 1500 ft·lb
G10 400 – 2000 N·m
G11 600 – 3000 ft·lb
G12 800 – 4000 N·m
G13 1000 – 5150 ft·lb
G14 1400 – 7000 N·m
Table 5.3: Calibration Mode Gearbox Values