4.2 Torque Operation
To operate the tool in a Torque Cycle:
1. Ensure the tool is in Torque Select mode (example in Figure 4.2-1.
Also see Section 3.1 – Changing Torque).
2. Ensure the LED Display is showing the correct units (see Section 3.2.1
– Change the Torque Units).
3. Change the torque value as desired (see Section 3.1 Changing
Torque). Allow the display to flash after changing the torque,
indicating that the torque value is saved and set.
4. The B-RAD Select is ready to torque at the displayed setting. Place
the B-RAD on the joint system.
Figure 4.2-1: Torque Select Mode
5. Ensure the Forward/Reverse Switch is in the Forward position.
6. Press and release On/Off Trigger to ensure tool is awake.
7. Press and hold the On/Off Trigger.
Note: To stop the Torque Cycle at any time, release the On/Off Trigger.
8. When the B-RAD reaches the selected Torque, the tool will stop turning. Release the On/Off Trigger.
5. CALIBRATION
CAUTION!
Only qualified personnel with training in the safe operation of torque tooling and the B-RAD Select Tool
System should operate this tool. Improper use of the calibration function will result in tool damage.
Do not calibrate at Target Torques that result in exceeding the B-RAD Select Tool System’s Torque Range.
Severe tool damage will occur.
This function allows the operator to access the calibration values for the B-RAD. These values should only
be modified by a Qualified Calibration Technician and using a Calibration Stand.
5.1 Calibration Menu Navigation
The functions available in Calibration depend on which Unlock level the
B-RAD Select is in. See Section 3.4 – Unlock Levels for details.
To enter the Calibration menu:
While in Torque Select mode, hold the button and press the
button. Make sure to release the button first. The “Tool” menu will
appear (Figure 5.1-1).
Figure 5.1-1: Tool (Calibration) Menu
To change numeric values within each menu:
Press and hold either the or the button until a digit flashes. Repeat until the desired digit is flashing,
then use the or button to change the number.
To exit the edit mode, press and hold either button. The value will be saved and the cursor will stop flashing.