3.4 Unlock Levels
The B-RAD Select has several access levels which change the operation of the tool and the interface. The access
levels are described below. The codes may be entered using the Lock Code menu (see Section 3.2.5 – Enter a
Lock or Unlock Code). After the code is entered and the menu is closed, the level is displayed on the LED display.
If the wrong code is entered, no message will be displayed after exiting.
Access
Level
Displayed
Name
How to use the
Code
Description Code
Torque
Mode
(Default
Mode)
Basic
Used to switch to
Torque Mode.
(This is the Default mode)
Basic Display Mode enables
setting the torque value.
Display torque in physical units
(ft·lb or N·m) as calibrated.
Table
Mode
Select
Used to switch to
Table Mode.
Select Display Mode enables
selecting 50 evenly spaced
torque levels over the calibrated
range.
Locked
Lock
Code is used to
lock and unlock
current mode.
Locking the tool freezes the
selected Display Mode.
Information Menu: Unit
Select, Battery level, Heat, LED
brightness, Code entry, and
Program version available.
Tool Menu: disabled
Easy-
Calibrati
on
Calibr
Used to switch to
Easy-Cal.
Change calibration values. See
Section 5 – Calibration.
Contact Us or your RAD
distributor
Table 3.4: Access Levels, Features, and Codes
4. GENERAL OPERATING INSTRUCTIONS
CAUTION!
Only qualified personnel with training in the safe operation of torque tooling and the B-RAD Tool System
should operate this tool. Refer to the Important Safety Notice for more information.
The B-RAD operates in Torque Cycles. The Torque Cycle passes when the Actual Torque reaches the Target
Torque, and the Cycle fails if it is interrupted before the Actual Torque reaches the Target Torque.
This section instructs the operator in the use of the Reaction Arm needed for B-RAD operation and how to
conduct a Torque Cycle.
4.1 Reaction Arm
Warning!
Always keep body parts clear of the Reaction Arm when the B-RAD Tool System is in use.
Serious injury could occur.
CAUTION!
Ensure that the Reaction Arm has a solid contact point before operating the B-RAD Tool System.
Improper reaction will void warranty and can cause premature tool failure.
Please contact New World Technologies Inc. or your local RAD Authorized Distributor for information on custom
Reaction Arms.