Tus neeg siv phau ntawv
B-RAD Select
USER MANUAL
New World Technologies Inc. Page 15
V2022.06.20
3.2.5 Enter a Lock or Unlock Code
1. Move to the next menu item: “Lock.”
The flashing line indicators on the
screen keep track of the number of
button presses used to enter a code
(Figures 3.2.5-1 and 2).
2. Enter a code using the and
buttons. The desired code will
depend on which features are
needed. See Section 3.4 – Unlock
Levels for more information.
Figure 3.2.5-1: Lock Menu
Figure 3.2.
5
-
2: Code Entry
–
Button
Presses
3. Navigate forward or press and hold both buttons to accept the code and close the menu. The new Unlock
level will scroll across the screen.
3.2.6 View Program Version
Move to the next menu item, labelled “Prog.” The program version number
will scroll across the screen.
Figure 3.2.5-1: Program Menu
3.3 Tool Menu
The Tool Menu displays tool model information and is the menu used to calibrate the tool. When in Locked or
Basic levels, you may only view tool information. When in Easy Calibration access level, the Cal Points may be
modified. The menu items are described in more detail in Section 5 – Calibration.
To enter the Tool Menu:
While in Torque Select mode, hold the button and momentarily press the button.
To move to the next item, hold the button and press the button. To go to a previous menu item, hold
the button and press the button.
To exit the menu, hold both buttons until the display flashes and the Torque Value is displayed. Any changes
made in Calibration will be saved.
To view tool information:
The first menu item is “Tool.” This displays the gearbox number and model in the calibrated units.
Move to the next menu item. The tool serial number is displayed.
The next two items display the minimum and maximum torque values.
If in Calibration mode, the next options define the minimum and maximum Calibration limits and the
Calibration Points. Changing these values will affect the output torque. See Section 5 – Calibration.