System information

Chapter 3 Configuration Management User's Manual
3-40 Additional Tasks Vmux-210 Ver. 1.0
Table 3-24. Bundle Connection Details SW Cfg 4 Connection Parameters (Cont.)
Parameter Possible Values/Remarks
Ring I 4th LSB Nibble, representing the RING PATTERN 1 signal
0000..1111
Default: 1011 (DCBA)
Note: This parameter is enabled for FXS ports only.
Ring II 5th LSB Nibble, representing the RING PATTERN 2 signal
0000..1111
Default: 1011 (DCBA)
Note: This parameter is enabled for FXS ports only.
Reverse Polarity 3rd LSB Nibble, representing the REVERSE POLARITY signal
0000..1111
Default: 1001 (DCBA)
Note: This parameter is enabled for FXS ports, when Pulse Metering is enabled.
Pulse Metering 6th LSB Nibble, representing the PULSE METERING signal
0000..1111
Default: 1001 (DCBA)
Note: This parameter is disabled when Reverse Polarity is enabled.
Ringback Disable, Enable
Default: Enable
Note: This parameter is enabled for FXS ports only.
Reverse Polarity Disable, Enable
Default: Disable
Note: This parameter is enabled for FXS ports, when Pulse Metering is disabled.
Immediate On-Hook
Detect While Ringing
Enables or disables immediate reaction to On-Hook bits from network, while
ringing
Disable, Enable
Default: Disable
Note: This parameter is enabled for FXS ports only.
Pulse Metering
Note: The following three Pulse Metering parameters are only enabled for a
Vmux-210 with at least 12 FXS ports, when Reverse Polarity is disabled.
Enable Enables or disables pulse metering synthesis
No, Yes
Default: No
Frequency (kHz) Frequency of synthesized pulse metering for this bundle
12, 16
Default: 16
Duration (msec) Duration of synthesized pulse metering
100..250
Default: 150
[Close] Click <Close> to close the dialog box.