System information
User’s Manual Chapter 7 Fault Management
Vmux-210 Ver. 1.0 Running Loopback Tests 7-21
Table 7-11. Test Parameters
Parameter Possible Values / Remarks
Port Link E1, Link T1, FXS
Current
Test Description of the test currently running.
E1/T1: Local Loop, Remote Loop, Test per TS, None
FXS: Remote Loop, Local Tone Injection, Remote Tone Injection, None
New
Disabled if a test
is currently
running.
Test Test description.
E1/T1: Local Loop, Remote Loop, Test per TS, None
FXS: Remote Loop, Local Tone Injection, Remote Tone Injection, None
Duration (sec) Duration of test to be run.
Infinite, 1…60
Default: Infinite (no time limit to test length)
Disabled for Local Loop and Remote Loop tests.
Test per TS
Enabled only if
Test is set to Test
Per TS in either
New or Current
group.
Time slot ID of the time slot to be tested
1…31 (E1), 1…24 (T1)
Test -- (None), LT (Local Tone Injection)
Duration -- (No test running), 1…60 (Duration of test in seconds), Inf (No time limit to test
length)
[Start Test] Click <Start Test> to begin testing a port
[Stop Test] Click <Stop Test> to stop the currently running test before its configured duration
[Close] Click <Close> to close the Port Test Dialog Box
[Refresh] Click <Refresh> to update the Port Test information