System information
Chapter 7 Fault Management User’s Manual
7-10 Monitoring Object Status Vmux-210 Ver. 1.0
Clearing All Levels of the Active Alarm Buffer
The Clear All command enables you to clear the alarm buffer at all levels.
To clear the Active Alarm buffer at all levels:
1. In Agent mode only, select the device.
2. From the Fault menu, select Alarms > Clear All.
•
Alarms that are masked are not cleared
•
If an alarm continues to be triggered for any reason, that alarm will not be
cleared because it will immediately reappear as soon as it is retriggered.
Configuring Alarm Attributes
The Configuration > Attributes command enables you to define alarms for each
level and set masking criteria for the alarms.
To configure Alarm Attributes:
1. In Agent mode only, select the device.
2. From the Fault menu, select Alarms > Configuration > Attributes.
3. Click the radio button next to the category of alarms you wish to display:
All alarms
System level alarms only
Port level alarms only (may be limited to a specific port)
IP Bundle alarms only (may be limited to a specific bundle).
The list of alarms displayed by default includes all active alarms for the
selected group plus any inactive alarms in that group with at least one
attribute set to Yes.
4. Sort the list of alarms by any one of the column values by clicking on the
column header. Each click toggles between ascending and descending order.
Note