Specifications
Chapter 4 Configuration Installation and Operation Manual
4-66 Additional Tasks Vmux-210 Ver. 1.1
Configuring Alarm LED Activation Level
To configure alarm parameters:
• From the Main Menu, select Configuration > System > Alarm Operations.
Alarm Operations
1. Alarm LED Severity> (Event)
Figure 4-69. Alarm Operations Menu
Table 4-60. Alarm Operations Parameters
Parameter Description Possible Values/
Reference
Alarm LED Severity Minimal alarm severity level for Alarm LED
activation
Event
Minor
Major
Default: Event
You can configure the alarm severity level that will cause the ALM LED to turn.
The following levels are available:
• Event. The LED will turn on whenever there is an "ON" alarm in the system, or
whenever an event has occurred. Since events are not state alarms, they do
not switch to the "OFF" state as soon as the problem that caused them is
solved, and you will have to clean the alarm buffer in order to turn the LED
off.
• Minor. At this level, events do not turn the LED on. As long as there are "ON"
alarms in the device (minor or major) the LED will be on, but as soon as all
the state alarms are turned off, the LED will automatically turn off (no need
to clean events from buffer).
• Major. At this level, neither events nor minor alarms turn the LED on. As long
as there are major "ON" alarms in the device the LED will be on, but as soon
as the major alarms are turned off, the LED will automatically turn off. There
is still no need to clean events from buffer.
To set the Alarm LED severity:
1. From the Main Menu, select Main > Configuration > System >
Alarm Operations > Set Alarm LED Severity.
The Set Alarm LED Severity menu appears (see
Figure 4-70
).
2. Select an alarm severity level; alarms at or above this level will turn on the
LED.