System information
IPmux-8/16 User’s Manual Chapter 3 Configuration Management
Configuring General Parameters 3-7
Configuring System Parameters
To set system parameters for the selected IPmux device:
1. Configuration > System Parameters...
The System Parameters dialog box appears (Figure 3-4).
2. Enter the required settings.
3. Click <Set> to implement the changes.
Figure 3-4. System Parameters Dialog Box
Table 3-4. System Parameters
Parameter Possible Values / Remarks
ToS Value IP ToS (Type of Service) assigned to this channel
0
–255
Configures IP ToS field in the IP frames transmitted by the device. Configures
the entire byte - not only the 3 ToS bits. ToS assignment applies to all TDM
packets leaving IPmux-16.
Default Gateway Gateway to which management frames will be sent (when the managers is not
in the host subnet)
LAN Redundancy These parameters exist for versions > 3.0. Parameters are disabled when two
E3/T3 cards are installed in Ipmux.
Active Interface LAN1=1025
LAN2=1057
Enforcement State Enables user to enforce a Link in spite of the redundancy mechanism
No Enforcement: Returns usual rules of the redundancy mechanism
LAN1: Main Link
LAN2: Backup Link
Note: Set Enforcement State by clicking [Enforced LAN] and selecting value.