Specifications

Chapter 5 Application Configuration Procedures IPmux-4 Installation and Operation Manual
5-18 Checking the Application
6. If you have underflows or overflows at non-set intervals of time:
Try to gradually increase the jitter buffer size.
Check that there are no E1alarms (such as LOS or LOF), through the IPmux
E1/T1 Statistics. If problems do exist on the E1/T1 level, check both physical
connections (cables and E1 ports) and E1/T1 parameter configuration
compatibility between the TDM equipment and the IPmux units (such as
CRC and CAS Enable/Disable).
Check that the Bundle connection configuration was made correctly.
For further information, see the IPmux Troubleshooting and Diagnostics chapter.
Step 2 – Using TDM Equipment Statistics and Functionality
After you have verified all the issues in Step 1, check the following:
1. Check that there are no alarms or BER on the TDM equipment.
2. If you are using a PABX check voice quality. IF echo exists, verify that you
haven’t configured the jitter buffer size to be too large (remember that the
initial configuration should be 3 ms, unless it is required to be larger due to
problems seen under the Bundle Connection Status).