Specifications
Site Requirements and Prerequisites 2-1
Chapter 2
Installation
2.1 Introduction
IPmux-4 is delivered completely assembled for bench-top installation. The only
mechanical installation procedure that may be necessary is optional installation in
a 19" rack. Refer to the Rack Mounting Kit for 19-inch Racks guide that comes with
the RM kit.
After installing the unit, configure the IPmux-4 using an ASCII terminal connected
to the IPmux-4 control port. The IPmux-4 configuration procedures are described
in Chapter 3 of this manual.
If problems are encountered, refer to Chapter 4 for test and diagnostics
instructions.
No internal settings, adjustment, maintenance and repairs may be performed
by either the operator or the user; such activities may be performed only by
skilled service personnel who are aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
2.2 Site Requirements and Prerequisites
AC-powered IPmux-4 units should be installed within 1.5m (5 feet) of an
easily-accessible grounded AC outlet capable of furnishing the required supply
voltage, in the range of 100 to 240 VAC.
DC-powered IPmux-4 units require a –48 VDC power source.
The DC power source must be isolated from the mains supply by double or
reinforced insulation.
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at
least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make
sure that the ventilation holes are not blocked.