Specifications
Chapter 1 Introduction IPmux-4 Installation and Operation Manual
1-18 Technical Specifications
Ethernet Port:
LINK OFF when line is not active
ON when line is OK
ACT OFF when no activity
ON when a frame is being transmitted or
received on the line
FDX OFF when half duplex
ON when full duplex
100M OFF when 10 MHz
ON when 100 MHz
E1/T1 Port:
SYNC ON when the port is synchronized (no alarm)
OFF when signal loss, LOF or AIS is detected
(local alarm)
BLINKS when RDI is detected (remote alarm)
Note: All LEDs are green and ON after power-up.
Power
Physical
Environment
Humidity
1 or 2 power supplies
30W, 100 to 240 VAC, 50/60 Hz
–36 to –72 VDC (–48 VDC nominal)
Height 4.4 cm / 1.7 in (1U)
Width 43.2 cm / 19 in
Depth 35 cm / 13.78 in
Weight 2.8 kg / 6.2 lb
Temperature: 0 to 45°C / 32 to 110°F
Up to 90%, non-condensing
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com