Specifications

FOM-E1/T1 Ver. 2.0 Detecting Errors 4-1
Chapter 4
Troubleshooting and
Diagnostics
This chapter describes the following FOM-E1/T1 diagnostic functions:
Front panel LED indicators
Alarm relays
Diagnostic loopbacks.
The chapter also provides tips on troubleshooting and frequently asked
questions.
4.1 Detecting Errors
Front Panel LEDs
The front panel LED indicators indicate the status of the FOM-E1/T1. For a
description of LED indicators and their functions, see
Chapter 3
.
Alarm Relays
FOM-E1/T1 has dry contact alarm relays. The following fault conditions trigger the
major and minor alarm relays:
A major alarm is initiated when E1/T1 electrical input drops below G.703
electrical levels, or the bit error rate at the fiber optic interface is higher than
10
-6
.
A minor alarms occurs when an Alarm Indication Signal (AIS) is received at the
E1/T1 electrical or fiber optic interfaces.
For information on the DB-9 connector pins used for the alarm relays, see
Appendix A
, table A-2.
When connecting an external alarm-monitoring device, do not exceed the
maximum rating of the alarm relay contacts (1A, 60 VDC, 30 VAC).
Note