Specifications

Chapter 4 Configuration RICi-4E1/T1, RICi-8E1/T1 Installation and Operation Manual
4-10 Configuring for Operation RICi-4E1/T1, RICi-8E1/T1 Ver. 2.0
Configuring Control Port Parameters
The terminal is connected to the Control port. The management software allows
you to configure the terminal baud rate.
The Baud Rate parameter is masked during a Telnet session.
³ To change the terminal baud rate:
1. Navigate to Main Menu > Configuration > System > Control Port.
The Control Port menu appears.
2. From the Control Port menu, select Baud Rate.
3. Select the desired baud rate. Available options are 9600, 19200 and 115200
bps (default).
4. Select Save.
RICi-4E1/T1, RICi-8E1/T1
Main Menu > Configuration > System > Control Port
1. Baud Rate > (115200 bps)
2. Save
>
ESC-Previous menu; !-Main menu; &-Exit
Figure
4-10. Control Port Menu
4.2 Configuring for Operation
The recommended operation configuration procedure includes the following
stages:
Setting device-level parameters
Setting logical layer parameters
Setting physical layer parameters.
Setting Device-Level Parameters
This section instructs you on selecting the clock source and the fault propagation.
Selecting the Clock Source
You can assign two sources of timing to the unit, a master clock and a fallback
clock that takes over if the master clock becomes unavailable. These timing
sources can be used to ensure that all devices in the network synchronize to a
single clock source.
You can assign the master and the fallback clocks as the unit’s internal clock or as
the clock for a specific E1/T1 link.