Specifications

Chapter 6 Troubleshooting and Diagnostics RICi-4E1/T1, RICi-8E1/T1 Installation and Operation Manual
6-14 Testing the Unit RICi-4E1/T1, RICi-8E1/T1 Ver. 2.0
If you entered a Multicast MAC address:
The Results screen appears as illustrated in
Figure
6-17
. The result
parameters are described in
Table
6-9
.
Select Replied Addresses to navigate to the Replied Addresses screen
(see
Figure
6-18
).
RICi-4E1/T1, RICi-8E1/T1
Main Menu > Diagnostics > OAM Tests > Loopback
1. Flow ID[1 - 8] ... (1)
Flow Name ... (Put your string here)
2. Destination Type (Destination Address)
3. Destination Address ... (00-11-B3-55-A6-77)
4. Number of LBs to Send[0 - 50] ... (0)
5. Send Loopbacks
6. Results >
Please select item <1 to 4>
F-Forward; B-Backward
ESC-Previous menu; !-Main menu; &-Exit; ?-Help
Figure
6-15. Loopback Menu – Destination Address
Table
6-8. Loopback Parameters – Destination Address
Parameter Possible Values Remarks
Flow ID 1 – 8 The ID of the virtual Ethernet connection.
Flow Name The name of the virtual Ethernet connection you chose.
Note: This parameter is read-only and cannot be configured.
Destination Type Destination Address
Remote MEP ID
The destination type for the loopback
Default: Destination Address
Destination
Address
The MAC address of the destination device
Number of LBs
to Send
0 – 50 The number of loopbacks.
Default: 0