Specifications

Chapter 4 Configuration RICi-4E1/T1, RICi-8E1/T1 Installation and Operation Manual
4-34 Additional Tasks RICi-4E1/T1, RICi-8E1/T1 Ver. 2.0
Parameter Possible Values Remarks
are: 1E-3,1E-4,1E-5,
1E-6,1E-7,1E-8,1E-9,1E-10
Default: 1, or 1E-10 for Unavailability Ratio /
Frame Loss Ratio
Sampling Interval 1 – 4294967296 The interval in seconds above which the data is
sampled and compared with the rising and falling
thresholds.
Note: This parameter is available only in the Frames
Above Delay and Frames Above Delay Variation
menus.
Event Reporting Type None
Log
SNMP Trap
Trap and Log
The Event type sent out after passing the threshold.
Default: None
4.3 Additional Tasks
This section describes additional operations available supported by the
RICi-4E1/T1, RICi-8E1/T1 management software, including the following:
Configuring MAC port protection
Setting the date and time
Displaying inventory
Transferring software and configuration files
Resetting the unit.
Configuring Date and Time
RICi-4E1/T1, RICi-8E1/T1 receives the date and the time from the network clock
using an NTP client. This causes the system to show the correct time and date
(and not the time of starting the system, which is the default.
³ To configure the NTP client:
Navigate to Main Menu > Configuration > System > Date and Time.