Table
4-16. Service Parameters
Parameter Possible Values Remarks
Service 1 – 3 Three services are automatically created for each
defined flow.
Performance Monitoring Enabled
Disabled
Enables/disables Performance Monitoring
Default: Disabled
Priority 0 – 7 Determines the P-bit value sent inside the OAM
message that originates from this service.
Default: 0
Delay Objective 1 – 1000 Determines the delay objective for the specified
service.
Default: 1
Delay Variation Objective 1 – 1000 Determines the delay variation objective for the
specified service
Default: 1
Frame Loss Ratio Refer to
Figure
4-35
and
Table
4-17
Frames Above Delay Refer to
Figure
4-35
and
Table
4-17
Frames Above Delay Variation Refer to
Figure
4-35
and
Table
4-17
Unavailability Ratio Refer to
Figure
4-35
and
Table
4-17
RICi-4E1/T1, RICi-8E1/T1
Configuration > Applications > OAM > End To End > Flows > MEP >
Services > Frames Above Delay
1. Rising Threshold ... (0)
2. Falling Threshold ... (0)
3. Sampling Interval ... (0)
4. Event Reporting Type ... (Trap and Log)
Please select item <1 to 1>
ESC-prev.menu; !-main menu; &-exit
Figure
4-35. Event Reporting Menu Screen
Table
4-17. MEP Services Event Reporting Parameters
Parameter Possible Values Remarks
Rising Threshold 1 – 4294967296
For Unavailability Ratio /
Frame Loss Ratio, the values
are: 1E-3,1E-4,1E-5,
1E-6,1E-7,1E-8,1E-9,1E-10
A value above this threshold within the sampling
interval for the specified counter will be considered
a rising event.
Default: 1, or 1E-10 for Unavailability Ratio /
Frame Loss Ratio
Falling Threshold 1 – 4294967296
For Unavailability Ratio /
Frame Loss Ratio, the values
A value above this threshold within the sampling
interval for the specified counter will be considered
a falling event.