Specifications
Installation and Operation Manual Chapter 4 API Reference
MiRIC-E1, MiRIC-T1 Ver. 1.5 SFP Identification Fields 4-9
5. Next byte is 0x00 for a write code operation.
6. Byte with content of 0x01 for the Length
7. Byte with content of 0x01 sets the LLB parameter
4.7 SFP Identification Fields
Table 4-6. MiRIC-E1/T1 SFP ID fields
Field name MIRIC-E1 MIRIC-T1
1. Vendor Name RAD data comm. RAD data comm.
2. Vendor OUI 0 0
3. Vendor PN MIRIC-E1 MIRIC-T1
4. Vendor Revision 1.5 1.5
5. Vendor S/N 0 0
6. Identifier SFP SFP
7. Ext.Identifier 04 04
8. Connector Unknown Unknown
9. Wavelength 0 0
10. Encoding Unspecified Unspecified
11. BR Nominal 0 0
12. BR Max 0 0
13. BR Min 0 0
14. Length 9/125 (km) 2 2
15. Length 9/125 (100m) 6 8
16. Length 50/125 (10m) 0 0
17. Length 62.5/125 (10m) 0 0
18. Length Copper (1m) 0 0
19. Year Data Code 0 0
20. Month Data Code 0 0
21. Day Data Code 0 0
22. VS Data Code 0 0
23. Diag Monitor Type 0 0
24. Enhanced Option 0 0
25. SFF 8472 Compliance 0 0
26. CC Base (Hex) DS E6
27. CC Ext (Hex) FF FF
28.Rate Select NO NO